|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
JQX- 102F CH0064847--2001 30.5x16.0x23.5 30.5x16.0x26.5 R2133344 Features Can be welded directly onto PCB. Used in household appliance like air conditioning , heater and instruments etc. Ordering Information JQX-102F A Z 20 b DC12V 0.9 1 2 3 4 5 6 1 Part numberJQX-102F 2 Contact arrangementA:1A 3 EnclosureZ: Dust cover 7 4 Contact ratingResistive:20A/250VAC 5 Terminalb:PC typeNIL:PC type and QC type 6 Coil rated Voltage(V)DC:5,12,24,48 7 Coil power consumption0.9:0.9W Contact Data Contact Arrangement Contact Material Contact Rating( Resistive) Max. Switching Power Max. Switching Voltage Contact Resistance or Voltage drop Operation Electrical life Mechanical 1A SPSTNO Ag SnO2 20A/250VAC 5000VA 300VAC 30m (at 1A/14VDC) 105 2y106 Max. Switching Current:20A Item 3.12 of IEC255-7 Item 3.30 of IEC255-7 Item 3.31 of IEC255-7 Coil Parameter Coil voltage VDC Pickup voltage VDC(max) (70%of rated voltage ) 3.5 8.4 16.8 33.6 release voltage VDC(min) (10% of rated voltage) 0.5 1.2 0.9 024-900 048-500 24 48 28.8 57.6 640 2560 2.4 4.8 20 10 Dash numbers Coil resistance 10% Coil power consumption W Operate Time ms Release Time ms Rated 005-900 012-900 5 12 Max. 6 14.4 27.8 160 CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria. 99 www.dblectro.com JQX-102F Operation condition Insulation Resistance Dielectric Strength Between contacts Between contact and coil Shock resistance Vibration resistance 1000M min (at 500VDC) Item 7 of IEC255-5 Item 6 Item 6 Item 8 of IEC255-5 of IEC255-5 of IEC255-5 50Hz 1500V 50Hz 4500V surge voltage:10kV Functional:200m/s2 11ms Survival:1000 m/s2 11ms 10~55Hz double amplitude Functional 1.5mm double amplitude Survival 2.0mm 10N 8N 235x2 3x0.5s -25~55 85% (at 40) 23g IEC68-2-27 Test Ea IEC68-2-6 Test Fc IEC68-2-6 Test Fc IEC68-2-21 Test Ua1 and Ua2 IEC68-2-20 Test Ta method 1 IEC68-2-3Test Ca Terminals strength Solderability Ambient Temperature Relative Humidity Mass Qualification inspection: Perform the qualification test as specified in the table of IEC255-19-1 and minimum sample size 24. Safety approvals Safety approval Load TuV 20A/250VAC COS =0.9 CCEE 20A/250VAC Dimensions (Unit: mm) mm 0.3 0.5 0.8 1.4 1.5 1.8 2 3.2 3.4 3.5 5.2 6.2 6.3 6.4 8.3 8.4 9.4 10 10.2 12 16 18.4 22 23.5 26.5 27.6 30.5 >acCa x x0.8 x x0.8 Dimensions Mounting (Bottom views) Wiring diagram (Bottom views) 0.012 0.020 0.031 0.055 0.059 0.071 0.079 0.126 0.134 0.138 0.205 0.244 0.248 0.252 0.327 0.331 0.370 0.394 0.402 0.472 0.630 0.724 0.866 0.925 1.043 1.087 1.201 NOTES 1).Dimensions are in millimeter. 2).Inch equivalents are given for general information only. www.dblectro.com |
Price & Availability of JQX-102F |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |